Minimizing iterations in field uniformity calibration for radiated immunity testing of electronic devices in a fully anechoic chamber

Valerii Semeniuk1, Talgat Gazizov1

1Tomsk State University of Control Systems and Radioelectronics.

DOI 10.24412/2410-9916-2026-4-105-121

PDF Full text

PDF XML JATS

Abstract

Purpose. Calibration of electric field uniformity in an anechoic chamber is essential for validation of electromagnetic compatibility testing. Existing iterative calibration methods often require a large number of iterations, which increases time costs and accelerates wear of measurement equipment. Applying root-finding methods to minimize the number of iterations can accelerate the calibration process; however, their efficiency and robustness under conditions close to real measurements remain insufficiently studied. The aim of this paper is to analyze root-finding methods for minimizing the number of iterations in field uniformity calibration with evaluation of their robustness to measurement uncertainties using the Monte Carlo method. Methods. Hybrid and bisection root-finding methods are used to minimize the number of iterations in the calibration process. The efficiency and robustness of the methods are assessed by Monte Carlo simulation, with measurement uncertainties artificially introduced into the computational experiment. The stopping criterion for the root-finding methods is reaching the specified electric field strength within a chosen tolerance. Novelty. The application of root-finding methods to minimize the number of iterations in field uniformity calibration while accounting for measurement uncertainty is proposed and validated, which reduces the time required for field uniformity calibration in a fully anechoic chamber. Results. A computational experiment was conducted to reach the required electric field strength with an accuracy of 0.1 V/m. Without uncertainties, the Dekker, Brent, and Bisection methods converged in 6.75, 9.25, and 7.25 iterations on average, respectively; the large errors of the Newton and secant methods are attributed to their sensitivity to the choice of initial guess. With measurement uncertainty taken into account, the Bisection method required the fewest iterations (4.75), while the Toms748 and Brent methods demonstrated the best accuracy and robustness to noise, contributing minimally to measurement uncertainty. Practical relevance. The advantage of hybrid and bisection methods for minimizing the number of iterations in field uniformity calibration has been established. The recommended methods reduce calibration time and test equipment wear without loss of accuracy. The proposed approach can be applied in the development and improvement of field uniformity calibration procedures for immunity testing of electronic devices in an anechoic chamber.

Key words

electromagnetic compatibility, field uniformity, calibration, measurement uncertainty, root-finding algorithms, Monte Carlo method.

Reference for citation

Semenuik V. A., Gazizov T. R. Minimizing iterations in field uniformity calibration for radiated immunity testing of electronic devices in a fully anechoic chamber. Systems of Control, Communication and Security, 2026, no. 4, pp. 105-121 (in Russian). DOI: 10.24412/2410-9916-2026-4-105-121

References

1. Amador E., Miry C., Bouyge N. Compatible Susceptibility Measurements in Fully Anechoic Room and Reverberation Chamber. 2014 International Symposium on Electromagnetic Compatibility. Gothenburg, Sweden, IEEE, 2014, pp. 860-865. DOI: 10.1109/EMCEurope.2014.6931024.

2. Lin H. N., Ho T. H., Chang W. Y., Kuo C. W. Design and Application of Novel Stripline for IC-EMC Characteristic Measurement. IET Science, Measurement & Technology, 2025, vol. 19, no. 1, pp.1-18. DOI: 10.1049/smt2.12228.

3. Komnatnov M. E. Method of Designing Devices Based on Transmission Lines for Testing Radioelectronic Equipment for Electromagnetic Compatibility. Doklady Tomskogo gosudarstvennogo universiteta sistem upravleniia i radioelektroniki [Proceedings of Tomsk State University of Control System and Radioelectronics], 2025, vol. 28, no. 2, pp. 42-54. DOI: 10.21293/1818-0442-2025-28-2-42-54 (in Russian).

4. Demakov A. V., Komnatnov M. E., Gazizov T. R. Review of Research in the Development and Application of Reverberation Chambers for Electromagnetic Compatibility Tests. Systems of Control, Communication and Security, 2018, no. 2, pp. 151-190. Available at: http://sccs.intelgr.com/archive/2018-02/09-Demakov.pdf (accessed 04.06.2026) (in Russian).

5. Hamann D., Garbe H., Pusch T., Suhrke M. A Detailed Study on TEM Waveguides' Field Distribution and Efficiency. 2015 IEEE International Symposium on Electromagnetic Compatibility (EMC). IEEE, 2015, pp. 881-886. DOI: 10.1109/ISEMC.2015.7256281.

6. Yao L., Lan W., Li D., Luo M. A Comparison of State-of-the-Art Evaluation Criteria for Field Uniformity Assessment. IEEE Transactions on Electromagnetic Compatibility, 2022, vol. 64, no. 6, pp. 1899-1905. DOI: 10.1109/TEMC.2022.3210174.

7. Carobbi C. F. M., Lallechere S., Arnaut L. R. Review of Uncertainty Quantification of Measurement and Computational Modeling in EMC part I: Measurement Uncertainty. IEEE Transactions on Electromagnetic Compatibility, 2019, vol. 61, no. 6, pp. 1690-1698. DOI: 10.1109/TEMC.2019.2904999.

8. Azpurua M., Paez B. E., Tremola C. A Proposed Method for Quantifying Uncertainty in RF Immunity Testing Due to EUT Presence. Progress In Electromagnetics Research B, 2011, vol. 29, pp. 175-190. DOI: 10.2528/PIERB11020802.

9. Catrysse J., Bogaerts J., Brandt J., Monteyne N., Paquet B., Pelt M. The Requirements of a Uniform Field Distribution for Radiated Immunity: A Critical Analysis. EMC'98 ROMA International Symposium on Electromagnetic Compatibility. IEEE, 1998, pp. 701-706. DOI: 10.23919/EMC.1998.10791743.

10. Camell D., Johnk R. T., Davis B. N., Taylor M. Verification of an EMC Facility Retrofit by Time-Domain and Field Uniformity Measurements. 2007 IEEE International Symposium on Electromagnetic Compatibility. IEEE, 2007, pp. 1-5. DOI: 10.1109/ISEMC.2007.103.

11. Friis H. T. A Note on a Simple Transmission Formula. Proceedings of the IRE, 1946, vol. 34, no. 5, pp. 254-256. DOI: 10.1109/JRPROC.1946.234568.

12. Trainotti V. Electromagnetic compatibility (EMC) Antenna Gain and Factor. IEEE Transactions on Electromagnetic Compatibility, 2017, vol. 59, no. 4, pp. 1006-1015. DOI: 10.1109/TEMC.2016.2642833.

13. Azpurua M., Tremola C., Paez B. E. Comparison of the GUM and Monte Carlo Methods for the Uncertainty Estimation In Electromagnetic Compatibility Testing. Progress In Electromagnetics Research B, 2011, vol. 34, pp. 125-144. DOI: 10.1109/CarpathianCC.2013.6560563.

14. Lallechere S., Carobbi C. F. M., Arnaut L. R. Review of Uncertainty Quantification of Measurement and Computational Modeling in EMC Part II: Computational Uncertainty. IEEE Transactions on Electromagnetic Compatibility, 2019, vol. 61, no. 6, pp. 1699-1706. DOI: 10.1109/TEMC.2019.2904999.

15. Melman A. Root Finding Techniques that Work. arXiv, 2022 DOI: 10.48550/arXiv.2204.02326.

16. Semenov K. K., Tselishcheva A. A. Generalized Interval Method of Bisection for Metrologically Based Search for Solutions of Systems of Equations with Inaccurately Specified Initial Data. Measurement Techniques, 2019, vol. 62, no. 3, pp. 193-201. DOI: 10.1007/s11018-019-01606-0.

17. Herzog A. An Iterative Equation Solver with Low Sensitivity on the Initial Value. Results in Control and Optimization, 2024, vol. 14, pp. 10-35. DOI: 10.1016/j.rico.2023.100351.

18. Zobiri F., Meslem N., Bidegaray-Fesquet B. Self-Triggered Stabilizing Controllers for Linear Continuous-Time Systems. International Journal of Robust and Nonlinear Control, 2020, vol. 30, no. 16, pp. 6502-6517. DOI: 10.1002/rnc.5123.

19. Pho K.-H. Improvements of the Newton-Raphson Method. Journal of Computational and Applied Mathematics, 2022, vol. 408. DOI: 10.1016/j.cam.2022.114106.

20. Argyros I. K., Khattri S. K. On the Secant Method. Journal of Complexity, 2013, vol. 29, no. 6, pp. 454-471. DOI: 10.1016/j.jco.2013.04.001.

21. King R. F. Anderson-Bjorck for Linear Sequences. Mathematics of Computation, 1983, vol. 41, no. 164, pp. 591-596. DOI: 10.2307/2007695.

22. Sabharwal C. L. An Iterative Hybrid Algorithm for Roots of Non-Linear Equations. Eng, 2021, vol. 2, no. 1, pp. 80-98. DOI: 10.3390/eng2010007.

23. Chandrupatla T. R. A New Hybrid Quadratic/Bisection Algorithm for Finding the Zero of a Nonlinear Function without Using Derivatives. Advances in Engineering Software, 1997, vol. 28, no. 3, pp. 145-149. DOI: 10.1016/S0965-9978(96)00051-8.

24. Dowell M., Jarratt P. A Modified Regula Falsi Method for Computing the Root of an Equation. BIT Numerical Mathematics, 1971, vol. 11, no. 2, pp. 168-174. DOI: 10.1007/BF01934364.

25. Brent R. P. Algorithms for Minimization without Derivatives. Mineola, New York, Dover Publications, 2013, 196 p.

26. Alefeld G. E., Potra F. A., Shi Y. Algorithm 748: Enclosing Zeros of Continuous Functions. ACM Transactions on Mathematical Software (TOMS), 1995, vol. 21, no. 3, pp. 327-344. DOI: 10.1145/210089.210111.

27. Virtanen P., Gommers R., Oliphant T. E., Haberland M., Reddy T., Cournapeau D., Burovski E., Peterson P., Weckesser W., Bright J., van der Walt S. J., Brett M., Wilson J., Millman K. J., Mayorov N., Nelson A. R. J., Jones E., Kern R., Larson E., Carey C. J., Polat I., Feng Y., Moore E. W., VanderPlas J., Laxalde D., Perktold J., Cimrman R., Henriksen I., Quintero E. A., Harris C. R., Archibald A. M., Ribeiro A. H., Pedregosa F., van Mulbregt P. SciPy 1.0: Fundamental Algorithms for Scientific Computing in Python. Nature Methods, 2020, vol. 17, no. 3, pp. 261-272. DOI: 10.1038/s41592-019-0686-2.

 

cc-by This article is distributed under a license Creative Commons Attribution 4.0 License.

cc0  The metadata of the article is distributed under a license CC0 1.0 Universal

 

О журнале

Выпуски журнала

2027:

Авторам

Рецензентам

Всем


На сайте работает система проверки ошибок. Обнаружив неточность в тексте, выделите ее и нажмите Ctrl + Enter.